JULY 2007 MAGNUM 224, MAGNUM 448, STORAGELIBRARY T24, OR STORAGELOADER 2U
A-19
ERRORS REPORTED OVER THE SCSI BUS
83h 03h T, L 14, 16,
12
Bad Label. Full Question. Label and full
status questionable. The library was
powered on or the cartridge access port
door was opened. The cartridge inventory
may have been violated. Issue an
INITIALIZE ELEMENT STATUS (07h or
E7h) command to reestablish the cartridge
inventory.
83h 09h O, T 10, 16,
12
Bad Label. No Label. The bar code
scanner could not read the bar code label
because there was no label on the
cartridge or the label was unreadable.
83h 0Ah L 12 Bad Label. Hardware Error. The library is
unable to read the bar code label due to a
bar code reader hardware error.
87h 21h 1Bh 4h D, L 8, 13, 12 Drive comm failed. The library is unable
to communicate with the tape drive.
87h 23h 1Bh 4h D, L 8, 13, 12 Drive comm timeout. The library is
unable to communicate with the tape
drive.
87h 24h 1Bh 4h D, L 8, 13, 12 Drive comm failed. The library is unable
to communicate with the tape drive.
87h 25h 12h 4h I 8, 13, 12 Drive not ready. The tape drive did not
return Ready status after a reset.
87h 26h 1Ah 4h D, L 8, 13, 12 Drive command error. The tape drive
failed to respond to a command from the
library.
Table A-3 REQUEST SENSE error information (ASC, ASCQ, FSC, and SK) (continued)
ASC
(byte 12)
ASCQ
(byte 13)
FSC
Sense
Key
Cause ERP SCSI Error Message and Description
Vista de pagina 250