A-16
SCSI REFERENCE 1014826
CHAPTER A—ERROR CODES
28h 01h 00h 06h I 10, 11 Not Ready to Ready. I/E Port accessed.
29h 00h 00h 6h I 10, 11 Power on or reset. A power-on, SCSI bus
reset, or Target Reset message occurred.
2Ah 01h 00h 6h I 10, 11 Mode parameters changed. Mode
parameters have been changed. Issue a
MODE SENSE (1Ah) command to
determine what the new mode
parameters are.
2Ah 02h 00h 6h I 10, 11 Log parameters changed. Log
parameters have been changed. Issue a
LOG SENSE (4Dh) command to
determine what the new log parameters
are.
30h 00h 16h, 1Fh 3h T, D 9, 14,
13, 12
Incompatible medium. (The media does
not have a compatible logical format.)
Incompatible media was ejected after a
LOAD command was issued.
Incompatible media was rejected after
the data cartridge was inserted.
3Bh 15h 29h 02h O 11 Magazine is unlocked. Operator may
change cartridges and close magazine.
3Bh 0Dh 18h, 1Ch 5h A, O 11, 6 Destination full. The destination element
was occupied for a MOVE MEDIUM
command. Redirect the cartridge loader
to a different location.
3Bh 0Eh 19h, 1Dh 5h A, O 11, 7 Source empty. The source element was
empty for a MOVE MEDIUM command.
Redirect the cartridge loader to a different
location.
3Fh 00h 13h 6h S, O 11 Operating condition changed. Over
temperature. The library’s internal
temperature is at a unsafe level for the
media.
Wait until the library has cooled, then
unload the cartridge to a cell and re-load
it into the tape drive.
Check the room temperature. The
ambient temperature must be no more
than 40°C (104°F).
Provide additional air flow around the
library to improve cooling.
Table A-3 REQUEST SENSE error information (ASC, ASCQ, FSC, and SK) (continued)
ASC
(byte 12)
ASCQ
(byte 13)
FSC
Sense
Key
Cause ERP SCSI Error Message and Description
Comentarios a estos manuales