5-2
SCSI REFERENCE 1014826
CHAPTER 5—INITIALIZE ELEMENT STATUS WITH RANGE (37h)
For best bar code scan results, refer to Magnum 224, StorageLibrary T24, or
StorageLoader 2U LTO Library Product Manual or the Magnum 448 LTO Library
Product Manual for information about positioning the bar code labels on data
cartridges.
Support for the INITIALIZE ELEMENT STATUS WITH RANGE command is
provided for compatibility. The library automatically re-establishes the cartridge
inventory immediately after power-on, whenever a magazine is inserted, or
whenever the cartridge access port door is opened, then closed again. Issuing a
INITIALIZE ELEMENT STATUS WITH RANGE command causes the library to
attempt reading any bar code labels that were unreadable during the most
current inventory operation.
The bar code scanner cannot scan a label on a cartridge that is loaded in the tape
drive.
5.2 WHAT YOU SEND TO THE LIBRARY
Fast – Byte 01, Bit 1
The library ignores this field. If a cartridge does not have a bar code label, the
cartridge inventory indicates that the label is unreadable.
Range – Byte 01, Bit 0
The Range field indicates which elements are to be checked, as follows:
Element Address – Bytes 02 and 03
This field specifies the address of the element or the starting address of a series
of elements to be checked. This field is ignored when the Range field is 0.
Magnum 224, T24, or SL 2U“Magnum 224, T24, or SL 2U Element
Addresses” on page 2-3 shows the default element addresses for the library.
Magnum 448“Magnum 448 Element Addresses” on page 2-5 shows the
default element addresses for the library.
Note: When the Range field is set to 1, the specified address must be a valid
element address.
Number of Elements – Bytes 06 and 07
This field indicates the maximum number of elements to be checked. This field
is ignored when the Range field is 0.
0 Initialize all elements
1
Initialize the range of elements specified by the Element
Address and Number of Elements fields