Quantum LTO 2U Instrucciones de operaciones Pagina 53

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 264
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 52
JULY 2007 MAGNUM 224, MAGNUM 448, STORAGELIBRARY T24, OR STORAGELOADER 2U
4-3
COMMAND STATUS
A request is made to scan a cartridge in a storage location and the operation
failed because the bar code scanner was unable to read the label on the
cartridge or if the cartridge does not have a label. The scan will not fail if the
location is empty. See Ta b l e 4 - 2 for details about how the cartridge inventory
is updated.
4.4 COMMAND STATUS
The library returns a status byte after processing the INITIALIZE ELEMENT
STATUS command as follows:
Good
The library returns Good status when it is able to process the command
without errors.
Busy
Busy status indicates that the library is temporarily unable to accept a
command from this initiator. The initiator may retry the command later.
Reservation Conflict
The library returns Reservation Conflict status when it is reserved by a
different initiator. See Chapter 20 for more information about the RESERVE
command.
Check Condition
Check Condition status is returned for the following reasons:
A Unit Attention condition is pending for the initiator.
The library has experienced an unrecoverable hardware error.
The library encounters a problem while scanning the cartridges.
The library is not ready because a magazine is removed.
Table 4-2 Effect on the cartridge inventory when a request for a cartridge scan fails
This cartridge inventory field...
...is changed to the following when the library cannot read the
cartridge label
Occupied 1
Occupied Valid 1
Label blanks
Label Valid 0
Label Scan Retries updated if retried
Source Storage Element Address no change
Vista de pagina 52
1 2 ... 48 49 50 51 52 53 54 55 56 57 58 ... 263 264

Comentarios a estos manuales