Quantum LTO 2U Instrucciones de operaciones Pagina 48

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 264
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 47
3-10
SCSI REFERENCE 1014826
CHAPTER 3—IMPLEMENTING SCSI OPERATIONS
The REQUEST VOLUME ELEMENT ADDRESS (B5h) command references
the Send Volume Match flag for the cell and sets it to 0 after the label
information is returned to the initiator. This flag is also set to 0 when the
library is reset or when the cartridge access port door is opened.
Tape Drive Accessible
The Tape Drive Accessible flag indicates whether the tape drive is empty, a
cartridge is loaded in the tape drive, or the cartridge is ejected, as follows:
This flag is set to 0 when the library loads a cartridge in the tape drive and
after the library is reset or the cartridge access port door is opened.
This flag is set to 1 when the library detects that the tape drive is accessible.
The library can detect that the drive is accessible after a move operation, after a
cartridge scan operation, or when the tape drive notifies the library that it is
accessible.
Cartridge Pick and Put Retry Counts
The Cartridge Pick Retry Counts and Cartridge Put Retry Counts fields
indicate the total number of pick/put operation retries for each element
location. These fields are cleared when the library is reset.
Total Number of Cartridge Puts
The Total Number of Cartridge Puts field indicates the total number of put
operations for each element location. Each time a cartridge is moved to an
element location, the total number of puts for that location is incremented.
This field is cleared when the library is reset.
Source Element Address
The Source Element Address field shows the address of the last storage
element from which the cartridge was moved.
3.5 MOVING CARTRIDGES
To instruct the library to move cartridges between a storage location and the
tape drive, issue the MOVE MEDIUM (A5h) command. The MOVE MEDIUM
command allows you to specify a source element address and a destination
element address for a specific move operation. See Chapter 11, “MOVE
MEDIUM (A5h).
0 A cartridge may be loaded in the drive
1
The drive is empty, or the cartridge is unloaded or ejected
and ready to be picked