Quantum LTO 2U Instrucciones de operaciones Pagina 213

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 264
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 212
JULY 2007 MAGNUM 224, MAGNUM 448, STORAGELIBRARY T24, OR STORAGELOADER 2U
22-1
22
SEND DIAGNOSTIC (1Dh)
22.1 ABOUT THIS COMMAND
The SEND DIAGNOSTIC command causes the library to perform its
diagnostic self-test. If a test is successful, the library returns Good status;
otherwise, it returns Check Condition status. When this command is followed
by a RECEIVE DIAGNOSTIC RESULTS (1Ch) command or a REQUEST
SENSE (03h) command, the results of the self-test are reported to the initiator.
Notes:
To ensure that the diagnostic data returned is valid, the SEND DIAGNOSTIC
command must be immediately followed by the RECEIVE DIAGNOSTIC
RESULTS command.
To ensure that the results of the diagnostic test are not destroyed by a command
sent by another initiator, the library should be reserved for the initiator’s
exclusive use.
The initiator must support the disconnect option if you plan to use the SEND
DIAGNOSTIC command because the library will disconnect from the initiator
while the command is executing.
Bit
Byte
7 6 5 4 3 2 1 0
00 00011101
01 Reserved PF RSVD SelfTest DevOfl UnitOfl
02 Reserved
03
Parameter List Length
04
05 00 Reserved 00
Vista de pagina 212