JULY 2007 MAGNUM 224, MAGNUM 448, STORAGELIBRARY T24, OR STORAGELOADER 2U
3-5
SETTING ELEMENT ADDRESSES
Press OK to reset the library. The library resets and performs a cartridge
inventory. When the reset is complete, the Home screen appears.
SCSI bus reset. SCSI Bus Reset is handled by the tape drive and only affects
the library indirectly through the ADI.
SCSI Target Reset message. SCSI Target Reset message is handled by the
tape drive and only affect the library indirectly through the ADI.
Note: If the library is performing a cartridge move operation when it is reset, it
completes the move operation during POST.
3.2.1 EFFECT OF POWER-ON RESETS
The power-on reset has the following effects:
The checksum of the flash code is validated.
All library parameters are reset to their default or saved values.
The library performs its power-on self-test.
A power-on reset of the library also resets the tape drive and causes them to
perform their power-on self tests.
After a power-on reset, the library will respond to SCSI commands as soon as
the tape drive is ready to respond on the SCSI bus.
3.2.2 EFFECT OF FRONT PANEL RESETS
A front panel reset has the following effects:
The checksum of the library’s flash code is validated.
All library parameters are reset to their default or saved values.
The library performs its power-on self-test.
After an operator panel reset, the library will respond to SCSI commands as
soon as the tape drive is ready to respond on the SCSI bus.
3.3 SETTING ELEMENT ADDRESSES
If you want, you can assign different element addresses to the library’s tape
drive(s), cartridge loader, I/E port, and cartridge cells (the data transfer,
medium transport, I/E port, and storage elements, respectively).
Magnum 224, T24, or SL 2U“Magnum 224, T24, or SL 2U Element
Addresses” on page 2-3 shows the default element address assigned to each
element in the library with two configurations.
Magnum 448“Magnum 448 Element Addresses” on page 2-5 shows the
default element address assigned to each element in the library with three
configurations.