3-8
SCSI REFERENCE 1014826
CHAPTER 3—IMPLEMENTING SCSI OPERATIONS
Magnum 448 Element Addresses The default element addresses for the
Magnum 448 library are listed in Ta b l e 3 - 2 . The addresses change when you
enable the I/E ports and the fixed cleaning cell. See “Magnum 448 Element
Addresses” on page 2-5 for additional information.
Element Occupied Status
The library uses the Occupied and Occupied Valid flags in the cartridge
inventory to determine whether a given element is occupied as follows:
Occupied The Occupied flag indicates whether the library considers the
specified element location to contain a data cartridge, as follows:
Occupied Valid The Occupied Valid flag indicates whether the Occupied flag
is accurate, as follows:
Table 3-2 Magnum 448 default element addresses
Element Type Default Element
Address
All storage elements 1h to 47h
Data transfer element
(tape drive)
Top half height
Third half height
Second half height
Bottom half height
54h
53h
52h
51h
Top full height
Bottom full height
52h
51h
Medium transport
(robot)
61h
I/E Port element
(cartridge access port)
a
a
If enabled.
Top I/E port
Bottom I/E port
72h
71h
0 The element location does not contain a data cartridge
1 The element location contains a data cartridge
0 The Occupied flag is questionable (may not be accurate)
1 The Occupied flag is accurate