Quantum LTO 2U Instrucciones de operaciones Pagina 58

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 264
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 57
5-4
SCSI REFERENCE 1014826
CHAPTER 5—INITIALIZE ELEMENT STATUS WITH RANGE (37h)
5.4 COMMAND STATUS
The library returns a status byte after processing the INITIALIZE ELEMENT
STATUS WITH RANGE command as follows:
Good
The library returns Good status when it is able to process the command
without errors.
Busy
Busy status indicates that the library is temporarily unable to accept a
command from this initiator. The initiator may retry the command later.
Reservation Conflict
The library returns Reservation Conflict status when it is reserved by a
different initiator. See Chapter 20 for more information about the RESERVE
command.
Check Condition
Check Condition status is returned for the following reasons:
A Unit Attention condition is pending for the initiator.
The library has experienced an unrecoverable hardware error.
The library encounters a problem while scanning the cartridges.
The library is not ready because a magazine is removed.
A parameter in the CDB is invalid (see Ta b l e 5 - 3 for sense data).
Label Scan Retries updated if retried
Source Storage Element Address no change
Table 5-2 Effect on the cartridge inventory when a request for a cartridge scan fails
This cartridge inventory field...
...is changed to the following when the library cannot read the
cartridge label
Table 5-3 Invalid parameters in the INITIALIZE ELEMENT STATUS WITH RANGE CDB
Sense
Key
ASC ASCQ
SKSV
Bit
C/D
Bit
BPV
Bit
Bit
Pointer
Field
Pointer
Error
5h 24h 00h 1 1 1
A reserved bit is set in the CDB. The
pointers point to the bit in error.
Vista de pagina 57
1 2 ... 53 54 55 56 57 58 59 60 61 62 63 ... 263 264

Comentarios a estos manuales

Sin comentarios