JULY 2007 MAGNUM 224, MAGNUM 448, STORAGELIBRARY T24, OR STORAGELOADER 2U
19-19
COMMAND STATUS
Good
The library returns Good status when it is able to process the command
without errors.
Busy
Busy status indicates that the library is temporarily unable to accept a
command from this initiator. The initiator may retry the command later.
Reservation Conflict
The library returns Reservation Conflict status when it is reserved by a
different initiator. See Chapter 20 for more information about the RESERVE
command.
Check Condition
The library returns Check Condition status for the following reasons:
The command is issued to an invalid LUN.
A Unit Attention condition is pending for the initiator.
A reserved bit is set to 1 in the CDB.
The library is not ready because a magazine is removed or the library is
operating in panel mode.
A parameter in the CDB is invalid (see Table 19-3 for sense data).
Table 19-3 Invalid parameters in the REQUEST VOLUME ELEMENT ADDRESS CDB
Sense
Key
ASC ASCQ
SKSV
Bit
C/D
Bit
BPV
Bit
Bit
Pointer
Field
Pointer
Error
5h 24h 00h 1 1 1
A reserved bit is set in the CDB. The
pointers point to the bit in error.
5h 21h 01h 1 1 0 0 0002h Invalid starting element address.
5h 24h 00h 1 1 1 3h 0001h Invalid element type code.